Flow Cytometer FM-FC-A100
www.fison.com |
[email protected]
Description :
Flow Cytometer FM-FC-A100 operates at flow speed ranging from 15 to 235 μL/Min enabling processing of different sample volumes. It is equipped with dual semiconductor lasers 488 nm, 638 nm, and 6 fluorescence channels. Our cytometer offers high-performance analysis of particles from 0.2 to 60 μm. Integrated with clinical Laboratory Information
System
(LIS)
for
data
transmission
and
graphical
representation, enhancing accessibility.
Features:
Automated liquid path maintenance Multi-parametric analysis Incorporated with Avalanche Photodiode Detector Bilingual software Features quick and auto compensation calculation Offers multiple single-color antibodies
Specifications:
Wavelength Laser Laser Power Fluorescence Channels
488nm, 638nm Semiconductor laser 488 nm & 638 nm laser: 20mW 40/60mW (Optional) 6
488nm laser: 530/30 nm BP FITC, 585/42 nm BP PE, 700 BP Per CP/ PE-Cy 5, 785/55 nm BP PE-Cy7 638nm laser: 660/20 nm BP APC, 785/55 nm BP APCCy7 The excitation and receiving of solid spatial separation. No fiber conduction. Fixed optical path.
Filters Configuration
Optics
Sensitivity Fluorescence
of
FITC < 75 MESF PE < 55 MESF APC < 55 MESF
FSC Sensitivity
0.5 μm
SSC Sensitivity
0.2 μm
Range Particles Linear
of
0.2 μm to 60 μm ≥ 0.98
Resolution
CV ≤2%
Carry-Over
≤ 0.1% Avalanche Photodiode Detector(APD) 45,000 events/s; 96 well plates/30min
Detector Speed Minimum Volume Speed Sample Absolute Count Preheating Time Blending Mode
Sample of
10μL 15 to 235 μL/Min Volumetric method: Microspheres method <4min Whole plate; single pipe; interval mixing is set freely
Tube Numbers Loader
of
Type of Tube
Capacity Bottle
of
Liquid
Maintenance System
Software
Feature Software
of
Compensation
FCS Format Operational Environment Computer Operating System Voltage
40 tubes and 96 holes Standard flow pipe(12 × 75mm, 5ml) 96 - well plates(F,U,V type) Centrifugal tube (1.5ml, 2ml) Waste liquid barrel 6L,Sheath liquid drum 6L,Cleaning liquid drum 1L Liquid path maintenance automation Software has an edition in English and Chinese With the function of automatic quality control detection, the software can draw the Levey- Jennings curve automatically Support to be connected with clinical LIS software, to facilitate data graphic transmission Automatic saving mode against power failure Detection and analysis can run at the same time Compensation Matrix List Quick Compensation Auto Compensation Auto Compensation CalculationFCS 3.0 10°C to 35°C, 15 to 80 % RH Win10 pro 220 V, 50Hz
Dimension (W × D × H) Liquid Weight Host Weight Host System Weight
Tray
The host system: 44 × 43.5 × 52 cm The host system with leader: 57.2 × 53.3 ×52 cm Liquid tray: 44 × 32 × 45 cm 7 Kg
System
32 Kg
with
38 Kg
Leader
Applications:
Flow cytometer ideal for cell sorting, cell cycle analysis, cell viability assays, DNA content analysis, immunophenotyping,
Accessories:
Power Line ×1
Sheath Fluid External Pipeline×1 Waste Fluid External Pipeline×1 Sheath Shunt External Pipeline×1 Cleaning Fluid External Pipeline×1 Connecting Line Between Main Engine and Reagent Platform×1 USB Data Signal Cable×1 Reagent Platform×1 Sheath Fluid Bottle×1 Waste Fluid Bottle×1 Cleaning Solution Bottle×1 Centrifuge Tube Rack (40 wells)×1 Flow-through pipe Rack (40 wells)×1 Spare Fuses×2
Accessories Optional:
TheApc Detection Board
The Fitc Detection Board Side Detection Board Wdm Assembly Acquisition Board Assembly Light Blocking Needle Assembly Power Switch Assembly Buffer Components Vials Mixing Device Flow Pool Assembly Forward Pd Lens Assembly
Forward Detection Board Assembly Reagent Bench Section