Are you struggling through the HCIA-Data Center Facility Certification Exam Preparation and wish there was an easy way to get through? Your prayers have been heard Dumpspedia comes with exciting new ways to learn HCIA-Data Center Facility V1.0 terms and concepts through Huawei Practice Tests. You can now rest assured, for you have a guaranteed source of success in your pocket H12-411 Practice Exam Dumps. H12-411 Practice Test Questions are all that you need to pass your exam with single try.
Dumpspedia
H12-411 Questions and Answers
Dumpspedia
H12-411 Questions and Answers
H12-411 Questions and Answers
Dumpspedia
H12-411 Questions and Answers
Dumpspedia
H12-411 Questions and Answers
Question NO 1 Administrators can not control the login time and login IP address of other users through Huawei NetEco. A. True B. False Answer: B
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 2 If the capacity of the UPS is 20KVA, the UPS front end input capacity may be () during normal operation. A. 20KVA B. 19KVA C. 18KVA D. 25KVA Answer: D
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 3 The humidifier that Huawei row-level precision air conditioner uses is the infrared humidifier. A. True B. False Answer: B
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 4 () support according to the report template to create a report task. A. Configuration Management B. Asset Management C. Report Management D. Stock Management Answer: C
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 5 Users can use the () function to assign personnel to troubleshoot A. Performance Management B. Monitoring and Management C. Work Order Management D Configuration Management Answer: C
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 6 When the load is 60KW, the capacity of each UPs is 100KVA, the power factor is 0.95, when the system must be redundancy configuration, how many UPS does it need at least? A. 2 B. 3 C. 4 D. 5 Answer: A
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 7 Air energy efficiency ratio is the ratio of effective input power and cooling capacity, its value will be shown as W/W. A. True B. False Answer: B
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 8 pPUE (Partial PUE) is an extension of the data center PUE, used to evaluate and analyzing the energy efficiency of a data center's local area or equipment. A. TRUE B. FALSE Answer: A
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 9 In battery construction, the () component functions can discharge excess gas. A. battery slot B. Pole C. safety valve D. Electrolyte Answer: C
www.dumpspedia.info/H12-411-questions-dumps.html
Question NO 10 Huawei monitoring system NetEco supports to send the alarm message to users through (). (Multiple Choice) A. Mail B. SMS C. Telephone D. Fax Answer: A B
www.dumpspedia.info/H12-411-questions-dumps.html
Dumpspedia
H12-411 Questions and Answers
Dumpspedia
H12-411 Questions and Answers
Dumpspedia
H12-411 Questions and Answers
Dumpspedia
H12-411 Questions and Answers
www.dumpspedia.info/H12-411-questions-dumps.html
H12-411 Dumps
Huawei H12-411 HCIA-Data Center Facility V1.0
Are you struggling through the HCIA-Data Center Facility Certification Exam Preparation and wish there...