Brochures-COUNTING SCALE OPERATION MANUAL
Maintenance manual
Details:
ACS-1.5/ACS-3/ACS-6/ACS-15/ACS-30 TCS-60/TCS-150 ACS SERIES COUNTING SCALE
Contact Us Zhangshan Hengxing Electronic
Co., Ltd.
OPERATION MANUAL
Address:2 Yongqiang Rd,
Zhaolong Industrial Park,Dongsheng Zhongshan528414 Guangdong China Tel:0760-22821378 0760-22229872 0760-22224078 Fax:0760-22229873 Zip code:528414 E-mail:
[email protected]
User Guidance
: Press
key to subtract the weight of pan and packing material in the pan,such as
trays,bags etc.Then the tare arrow will point at ,put the goods on the pan,and the the net weight will be displayed in the screen.After removed the goods and packing material,negative value will be displayed,press
again to return zero, the T mark will point at Õ 0←
Press this key to set sample quantity. Input the sample unit weight and press
key if you know the sample unit weight.
Number alarm.You can use this key to pre-set the number you need,when the quantity reach or exceed the pre-set number,the scale will send out alarm voice automatically. Weighing alarm.You can use this key to pre-set the weight you need,when the weight reach or exceed the pre-set weight, the scale will send out alarm voice automatically. Press this key to clear the data. Press this key together with M1-M3 key to save unit weight into memory Backlight.
1. Parameter Setting Turn on the scale and press
key for 1s or more until the scale enters parameter setting state,
if you need to set division,press
key,if set auto on/off,press
key,
Two division available:H:1/30000 L:1/15000 Auto off: A-0 ; No auto off A-1 Auto shut down in 15
2. Screen Brightness Adjustment Press
2 different brightess can be choosed
3. Battery Status You can directly see the battery status from the battery mark in Unit Price screen. four battery level,
two battery level
4. Counting Function The following methods will let you know the quantity of the goods going to be weighed. 1. if you know the sample unit weight: Turn on the scale ¯ Place the goods on the pan ¯ Input the unit weight,the data in the Unit Weight screen flickers,press ¯
to confirm.
2. You can also weight the sample to know the unit weight: Turn on the scale ¯ Place the articles on the pan ¯ Unitil the reading is stable, input the number of sample and press Unit weight and total number screen flickers,Press
to confirm,the readings in the
to confirm (in order to make the reading
more accurate, you can put more samples on the pan,and press to see the Unit Weight and Total number.) ¯ The unit weight and Total number screen will show the unit weight and quantity ¯ Take off the samples, and place the goods on the pan.The Unit weight and Total number will be displayed in the screen. ¯
Set Quantity Alarm Turn on the scale and place the goods on the pan ¯ Press
, the Weight screen will show”nn”, The Unit weight , total number screen will show-----,
input your expected quantity, and press
again to confirm.
(if the input quantity is not as your expected, press to cancel it) ¯ When the quantity reached your pre-set quantity, the alarm will sound. ¯ Turn on the scale,place the articals on the pan ¯ Press
the weight screen will show CC, the Unit weight, Total number screen wil show---, input
your expected weight, and press
key again to confirm.if the input weight is not as your expected,
press
to cancel it ¯ When the weight reached your pre-set weight,the alarm will sound
Specification Model
ACS series Counting scale
Capacity
1.5kg
3kg
6kg
15kg
30kg
60kg
150kg
D1
0.1g
0.2g
0.5g
1g
2g
5g
10g
D2
0.05g
0.1g
0.2g
0.5g
1g
2g
5g
Division
Counting scale
Power
DC 9V/500mA , battery 6V 4AH
Condiction
Temperature 0 C-40 C,Humidity<80%RH
Pan size
200x280mm; 230x300nn
platform
Alarm Warning message ---- (overweight) "Err" is displayed Battery mark
Reason Exceed the weight range(over 9 division) The G.W beyond the sensor' s max weight Not enough power
winks
Charge Notice
The scale have battery protection function. When the battery is low, the scale will be turned off automatically. If do not charge in time, the scale will automatically shut down in 30 seconds after restarted. When you charge the battery, please connect the adapter cable(DC9V/500mA) with the scale socket, the pilot light will light up. (if the scale is not intended for use for long time, please charge the battery every three month). It will need 8-10 hours to full charge the battery. You can see the charging status according to the charge pilot light: Color of the Pilot light
Red
Yellow
Green
Charging Rate
50%~80%
80%~90%
90%~100%
Close